Testing Capabilities
S4A
Blow down hypersonic wind tunnel with axisymetric nozzles, Mach 6 to Mach > 10
The Modane S4A wind tunnel produces an airflow at a maximum stagnation pressure of 120 bar and a maximum stagnation temperature of 1600 K.
Run duration up to 90 seconds (with 8000 m3 vacuum downstream tank at 20 mbar).
- Compressed air: 270 bar, 109 m3 upstream storage tanks, repressurized by a 5.7 kg/s mass airflow compressor.
- Vacuum: 20 mbar minimum pressure, 4000 or 8000 m3 storage tanks.
Instrumentation and measurement methods
- Data acquisition system with 48 to 72 analog channels, and possible extension up to 120 channels by adding simplified channels for thermal measurements.
- Steady measurement.
- Unsteady measurement rate up to 30 kHz per channel.
- Pressure measurement by individual transducers or PSI® electro-pressure scanner: rate can reach 1,472 mean values every 10 seconds (the average value is calculated from a sample of 127 results per channel).
- Temperature measurement by thermocouples or infrared thermography.
- Force measurement by ONERA 6-components balances; numerous balances available and new ones manufactured on request; hinge moment measurement by appropriate balances.
- Flow visualization by steady or spark shadowgraph (800 mm field diameter), colored oils, infrared.
- Portable data acquisition and processing system designed to support off-line model preparation.
Test sections
Mach | 6 | 6,8 | 10 | M > 10 |
Outlet diameter (mm) | 900 | 900 | 990 | 990 |
Throat diameter (mm) | 114 | 84 | 37 | -- |
Maximum Reynolds number (L=1m) | 20.106 | 15.106 | 8.106 | 2,5.106 |
Maximum stagnation pressure (bar) | 30 | 53 | 140 | 115 |
Maximum stagnation temperature (K) | 700 | 680 | 1600 | 1600 |
Typical tests
Technical documentation